XEV8-150/750-W-1H3L

DC Contactor Rated working current: 150ADC Rated working voltage: 0-750VDC Polarity of main circuit: Polarity Auxiliary contact: NO
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
Product description
Parameters
Technical Parameters
Order specification number

This DC contactor is widely used in new energy vehicles, charging equipment, photovoltaic/wind power generation, energy storage equipment, cloud servers, high-speed rail, rail transportation,ships, aviation, robotics, industrial automation, etc.

This DC contactor (hereinafter referred to as contactor) is suitable for DC power supply, connection and breaking of DC power controller in the main circuit with the rated voltage of DC 750V and the rated current of DC 150A or less.
The arc extinguishing chamber cavity adopts vacuum brazed ceramic sealing technology, which has the characteristics of high voltage, high current, double insulation, small size and strong arc extinguishing ability, so as to ensure that the product does not catch fire or explode under proper use;
The main contacts are made of special copper alloy material,with strong breaking capacity, anti-adhesion and long life.
The arc extinguishing chamber cavity is filled with a certain pressure of inert gas mixture, which can effectively protect the main contacts, preventing them from oxidation and making them break more quickly.
The product has a built-in control coil energy saving device,which can reduce the energy consumption.
The overall protection level of the contactor can reach IP67 level.
The product implements GB/T 14048.4-2020 standard.
The product complies with IEC60947-4-1:2009 standard.
The product complies with EU RoHS requirements.

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Performance parameters

Product Model
XEV8-150/750-W-1H3L
Contact Rated current

DC 150A

Rated voltage

DC 12-750V

Contact structure

1H

Contact resistance

<0.3mΩ

Voltage drop of contact(load rated current)

Below DC 0.2V 

Max. switching current

1200A(Over 1 time)

Max. switching voltage

DC 1000V
Auxiliary contact

The form of auxiliary contact

-

The load rating of auxiliary contact

-

The minimum load of the auxiliary contact

-
Coil

Rated control voltage

DC 12~36V

Rated current

Start: 1.7~0.6A

Stay: 200~70mA

(Switch on time < 0.2s)

Coil resistance

3.18Ω

Consumed power

Start/Stay≈20W/2.5W

Pull-in voltage

Below 75% of the rated control voltage

Release voltage

Over DC 1V
Operation

Pull-in time

Below 40ms

Release time

Below 20ms

Dielectric properties

Insulation resistance

(DC1000V measuredby tramegge)

Between coil and contact

Over 1000MΩ

Between contact in the same polarity

Over 1000MΩ
Withstand voltage

Between coil and contact

AC 4000V 1Min.

Between contact in the same polarity

AC 3000V 1Min.

Impact resistance voltageImpact resistance voltage

[Measured under the pulsed voltage wave of(1.2x50μs)]

4800V

Mechanical properties

Shock proof

Malfunvtion Excitation

490m/s²

No Excitation

196m/s²

Durability

490m/s²

Vibration resistant

Durability

10~55~10Hz Single amplitude 0.75mm

(2.94~88.9m/s²)

Durability

10~55~10Hz Single amplitude 0.75mm

(2.94~88.9m/s²)

Life

Service life of electric

Resistive load

(360 times/hour)

Over 10000 times(DC 500V 150A)

Over 6000 times(DC 750V 150A)

Over 50 times(DC 1000V 100A)

Capacitive load

-

Mechanical service life (3600 times/hour)

Over 1 million times

Applied environmental temperature

-40~+85°C

Applied environmental humidity

5-85%RH

Weight (approx.)

410g

※ Control loop mode: set by the user;

※ Rated working system: long-term working system;

Description of model naming rules of XGVAC Contactor

Example:X EV 8 - 150   / 750   - W   - 1 H 3 L  

              ①    ③      ⑤  ⑥  ⑦   ⑧ ⑨  ⑩ ⑪⑫ ⑬⑭

NO.

Description

Corporate code

Contactor for new energy

Code of shape: "6" for square type, "8" for circular type

The rated working current for main circuit (DC A)

The function of auxiliary contact: "A" means that it has the function of auxiliary contact

The rated working voltage for main circuit (DC V)

The polarity for main circuit: "N"  is non-polarity

The control voltage of coil (DCV), "W" is the wide voltage

The input polarity of coil: "N" is non-polarity

The number of poles for the contact of main circuit

The structure of the contact of main circuit: "H" refers to normallyopen, "D" refers to normally close

The way of the leading-out terminal of main circuit: "3" refers to externally threaded bolt type, "4"  is inserting type, "5" means internally threaded bolt type, "6" refers to the combination of internal thread + connector 

The way of leading-out terminal of the coil: "L" is outgoing line type, "C" connector type, "B" is the combination of outgoing line+ connector type, "P"refers to the inserting type;

Derived code

 

Ordering Instructions

The following contents shall be stated when ordering:

1. Name, model and quantity of contactor;

2. Rated working voltage and rated working current of contactor;

3. Rated control power supply voltage of contactor;

Page up
1

Related Products

There is currently no content to display
Please add data record on website background.

Online message

Username used for comment:
客户留言
Description:
language
中国
韩国
韩国
韩国
韩国
韩国

Contact Us

Address: No. 2106, Nanfeng Road, Fengxian District, Shanghai
Tel:
(86-021)57595783
Fax: (86-021)58680999
E-mail:
xgv@xgvac.com

 

img img img img img
留言应用名称:
客户留言
描述:
验证码

Follow us

QR code

All rights reserved©XGVAC Technology (Shanghai) Co., Ltd.  沪ICP备17040339号-1