Technical Parameters
Order specification number

DC contactors can be widely used in new energy vehicles and energy storage equipment, charging equipment and photovoltaic, tidal, wind and other green energy power generation systems, rail transit, engineering vehicles, forklifts, leisure and tourism vehicles, cloud servers and UPS, medical equipment, Port electromechanical and construction electromechanical fields are mainly used to switch DC power supplies.

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Main technical parameters

Product model

XEV8-50/750-12N-1H5L
XEV8-50/750-24N-1H5L

Contact

Contact structure

1H

Rated current

DC 50A

Rated voltage

DC 12-750V

Contact resistance

<0.5mΩ

Voltage drop of contact

(load rated current)

Below DC 0.1V

Short-time power current

1.200A10 min; 2.300A 10 seconds

Overload cut-off

DC 450V 75A 50 times

Reverse cut-of

 

Max. switching current

DC 320V 350A (Over 1 time)

Max. switching voltage

DC 1000V

Coil

Rated control voltage

DC 12V、24V

Pull-in voltage

Below 75% of the rated control voltage

Release voltage

Over 75% of the rated control voltage

Consumed power

≈5.5W

Ope-ration

Pull-in time

Below 25ms

Release time

Below 10ms

Service life

Service life of electric (360 times hour)(resistive load)

10000 times (DC 450V 50A)

6000 times (DC 750V 50A)

Mechanical service life

(3600 times/hour)

Over 1 million times

Insulation resistance

(DC1000V measured by tramegger)

Between coil and contact

Over 1000MΩ

Between contact in the same polarity

Over 1000MΩ

Withstand voltage

Between coil and contact

AC4000V 1 min

Between contact in the same polarity

AC3000V 1 min

Applied environmental temperature (No freezing and no condensation)

-40-+85°C 

Applied environmental humidity

5-85%RH

Weight ( approximately )

300g

 

 

 Control loop mode: set by the user;

 Rated work system: long-term work system;

Schugway contactor Model naming rule description

Example: X E V 850  / 750 - 12 N - 1 H 5 L

                        ①        ③                        ⑥   ⑦     ⑧ ⑨ ⑩ ⑪ 

No. 

Instruction

Corporate code ;

Contactor for new energy;

Code of shape: “8” for circular type;

The rated working current for main circuit (DCA);

The rated working voltage for main circuit (DCV);

The control voltage of coil (DCV);

The input polarity of coil:“N”is non-polarity;

The number of poles for the contact of main circuit ;

The structure of the contact of main circuit:“H”refers
to normally open;

The way of the leading-out terminal of main circuit:
“5” means internally threaded bolt type;

The way of leading-out terminal of the coil:
“L” is outgoing line type.

 

Order information

The following should be stated when ordering:

1, contactor name, model, quantity;

2, the rated working voltage and rated working current of the contactor;

3the rated control power voltage of the contactor;

 

Note: When the model abbreviation is used, ⑥ - ⑪ can be omitted.

There is currently no content to display
Please add data record on website background.

Related Products

There is currently no content to display
Please add data record on website background.

Online message

Username used for comment:
客户留言
Description:
language
中国
韩国
韩国
韩国
韩国
韩国

Contact Us

Address: No. 2106, Nanfeng Road, Fengxian District, Shanghai
Tel:
(86-021)57595783
Fax: (86-021)58680999
E-mail:
xgv@xgvac.com

 

img img img img img
留言应用名称:
客户留言
描述:
验证码

Follow us

QR code

All rights reserved©XGVAC Technology (Shanghai) Co., Ltd.  沪ICP备17040339号-1