DC contactors can be widely used in new energy vehicles and energy storage equipment, charging equipment and photovoltaic, tidal, wind and other green energy power generation systems, rail transit, engineering vehicles, forklifts, leisure and tourism vehicles, cloud servers and UPS, medical equipment, Port electromechanical and construction electromechanical fields are mainly used to switch DC power supplies.

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Main technical parameters

Product model

XEV6-120/750-12N-1H6C
XEV6-120/750-24N-1H6C

Contact

Contact structure

1H

Contact resistance

<0.5mΩ

Voltage drop of contact(load rated Below  DC 0.1V

Service life of electric

current) Resistive load(360 times/hour

Over10000 times (DC 450V 120A)

Over6000 times (DC 750V 120A)

Capacitive load

Switch on for over 20000 times (DC37.5V,τ=1ms, Shock 180A,Steady state 120A) 

Rated current

DC 120A

Max.switching current

DC 630V 1000A(Over 1 time)

Max.switching voltage

DC 1000V

Coil

Rated control voltage

DC 12V, 24V

Rated current

DC 12V: 360mA

DC 24V: 143mA

Coil resistance

DC 12V: 33Ω

DC 24V: 132Ω

Pull-in voltage

Below 75% of the rated controlvoltage

Release voltage

Over 10% of the rated control voltage

Consumed power

≈5W

Ope-
ration5

Pull-in time

Below 50ms

Release time

Below 30ms

Impact resistance voltageImpact resistance voltage
(Measured under the pulsed voltage wave of(12x50μs) 

4000V

Mechanical service life (3600 times/hour)

Over 1 million times

Insulation resistance
(DC100V measured
by tramegger)

Between Coil and contact

Over 1000 MΩ

Between contact
 in the same polarity

Over 1000 MΩ

Withstand
 voltage 

Between Coil and contact

AC2500V 1 min

Between contact
 in the same polarity

AC2500V 1 min

Applied environmental temperature
(No freezing and no condensation)

-40-+85°C 

Applied environmental humidity

5-85%RH

Weight ( approximately )

320g

 Control loop mode: set by the user;

 Rated work system: long-term work system;

Schugway contactor Model naming rule description

Example: X E V 6120  / 750 - 12 N - 1 H 6 C

                        ①        ③                           ⑥   ⑦     ⑧ ⑨ ⑩ ⑪ 

No. 

Instruction

Corporate code ;

Contactor for new energy;

Code of shape:“6”for square type;

The rated working current for main circuit (DCA);

The rated working voltage for main circuit (DCV);

The control voltage of coil (DCV);

The input polarity of coil:“N”is non-polarity;

The number of poles for the contact of main circuit ;

The structure of the contact of main circuit:“H”refers
to normally open;

The way of the leading-out terminal of main circuit:
“6” refers to the combination of internal thread + connector ;

The way of leading-out terminal of the coil:
"C" connector type.

 

Order information

The following should be stated when ordering:

1, contactor name, model, quantity;

2, the rated working voltage and rated working current of the contactor;

3the rated control power voltage of the contactor;

 

Note: When the model abbreviation is used, ⑥ - ⑪ can be omitted.

There is currently no content to display
Please add data record on website background.

Related Products

There is currently no content to display
Please add data record on website background.

Online message

Username used for comment:
客户留言
Description:
language
中国
韩国
韩国
韩国
韩国
韩国

Contact Us

Address: No. 2106, Nanfeng Road, Fengxian District, Shanghai
Tel:
(86-021)57595783
Fax: (86-021)58680999
E-mail:
xgv@xgvac.com

 

img img img img img
留言应用名称:
客户留言
描述:
验证码

Follow us

QR code

All rights reserved©XGVAC Technology (Shanghai) Co., Ltd.  沪ICP备17040339号-1