(Summary description)Before installing a Discount 1000V DC Contactor from China, the originals should be carefully checked, and a contactor with intact parts and a complete arc chute should be selected. When there is no problem with the appearance, you can remove the arc extinguishing cover and press the contacts of the Discount 1000V DC Contactor with your fingers to ensure that the contact structure inside the contactor should be able to move sensitively and not get stuck.

What are the precautions for the installation of Discount 1000V DC Contactor from China

(Summary description)Before installing a Discount 1000V DC Contactor from China, the originals should be carefully checked, and a contactor with intact parts and a complete arc chute should be selected. When there is no problem with the appearance, you can remove the arc extinguishing cover and press the contacts of the Discount 1000V DC Contactor with your fingers to ensure that the contact structure inside the contactor should be able to move sensitively and not get stuck.

  • Categories:News
  • Author:
  • Origin:
  • Time of issue:2022-08-15
  • Views:0
Information

Before installing a Discount 1000V DC Contactor from China, the originals should be carefully checked, and a contactor with intact parts and a complete arc chute should be selected. When there is no problem with the appearance, you can remove the arc extinguishing cover and press the contacts of the Discount 1000V DC Contactor with your fingers to ensure that the contact structure inside the contactor should be able to move sensitively and not get stuck.

Discount 1000V DC Contactor from China
When pressing, try to use your fingers to press the main contacts at the same time, and pay attention to observe whether the contact between the head moving contacts and the main static contacts of the Discount 1000V DC Contactor from China is normal, and there should be no inclination, gap or unevenness. When installing a DC Contactor, the inclination should not exceed 50 degrees, otherwise it may affect the use of the contactor. The screws for fixing the Discount 1000V DC Contactor should be equipped with a spring V-ring and a flat V-ring to prevent the contactor from loosening.
After the installation is completed, pay attention to check whether the main contact and auxiliary contact of the 1000V DC Contactor from China are connected correctly, and turn on the power to try to start and stop the contactor several times. After confirming that the Discount 1000V DC Contactor is running normally, it can be put into operation with load.

Keyword:

Scan the QR code to read on your phone

language
中国
韩国
韩国
韩国
韩国
韩国

Contact Us

Address: No. 2106, Nanfeng Road, Fengxian District, Shanghai
Tel:
(86-021)57595783
Fax: (86-021)58680999
E-mail:
xgv@xgvac.com

 

img img img img img
留言应用名称:
客户留言
描述:
验证码

Follow us

QR code

All rights reserved©XGVAC Technology (Shanghai) Co., Ltd.  沪ICP备17040339号-1