XEV6-100A/1500N-12(24)-1H6L

DC Contactor Rated working current: 100ADC Rated working voltage: 0-1500VDC Polarity of main circuit: Nopolarity Auxiliary contact: YES

The forward and reverse attack rates of the recirculating ball steering gear are very high, so it is easy to operate, has a long life, and works stably and reliably; however, due to the high reverse attack rate, it is easy to transmit the road impact to the steering wheel


Key words:

XEV6-100A/1500N-12(24)-1H6L

E-mail: xgv@xgvac.com

  • 产品描述
  • Technical Parameters
  • Order specification number
    • Commodity name: XEV6-100A/1500N-12(24)-1H6L

    DC Contactor Rated working current: 100ADC Rated working voltage: 0-1500VDC Polarity of main circuit: Nopolarity Auxiliary contact: YES

    This DC contactor is widely used in new energy vehicles, charging equipment, photovoltaic/wind power generation, energy storage equipment, cloud servers, high-speed rail, rail transportation,ships, aviation, robotics, industrial automation, etc.

    This DC contactor (hereinafter referred to as contactor) is suitable for DC power supply, connection and breaking of DC power controller in the main circuit with the rated voltage of DC 1500V and the rated current of DC 100A or less.
    The arc extinguishing chamber cavity adopts vacuum brazed ceramic sealing technology, which has the characteristics of high voltage, high current, double insulation, small size and strong arc extinguishing ability, so as to ensure that the product does not catch fire or explode under proper use;
    The main contacts are made of special copper alloy material,with strong breaking capacity, anti-adhesion and long life.
    The arc extinguishing chamber cavity is filled with a certain pressure of inert gas mixture, which can effectively protect the main contacts, preventing them from oxidation and making them break more quickly.
    The product has a built-in control coil energy saving device,which can reduce the energy consumption.
    The overall protection level of the contactor can reach IP67 level.
    The product implements GB/T 14048.4-2020 standard.
    The product complies with IEC60947-4-1:2009 standard.
    The product complies with EU RoHS requirements.

  • Performance parameters

    Product Model
    XEV6-100A/1500N-12-1H6L
    XEV6-100A/1500N-24-1H6L
    Contact Rated current

    DC 100A

    Rated voltage

    DC 12-1500V

    Contact structure

    1H

    Contact resistance

    <0.3

    Voltage drop of contact(load rated current)

    Below DC 0.1V 

    Max. switching current

    800A(Over 1 time)

    Max. switching voltage

    DC 1800V
    Auxiliary contact

    The form of auxiliary contact

    1H

    The load rating of auxiliary contact

    DC 30V 2A / AC 125 3A

    The minimum load of the auxiliary contact

    DC 8V 100mA
    Coil

    Rated control voltage

    DC 12、24V

    Rated current

    Start/Stay DC 12V: 6.1A/376mA

    DC 24V:3.06A/188mA

    (Switch on time<0.2s)

    Coil resistance

    Start/Stay DC 12V:1.96Ω/31.94Ω

    DC 24V:7.84Ω/127.8Ω

    Consumed power

    Start/Stay≈73W/4.5W

    Pull-in voltage

    Below 75% of the rated control voltage

    Release voltage

    Over 10% of the rated control voltage
    Operation

    Pull-in time

    Below 50ms

    Release time

    Below 30ms

    Dielectric properties

    Insulation resistance

    (DC1000V measuredby tramegge)

    Between coil and contact

    Over 1000MΩ

    Between contact in the same polarity

    Over 1000MΩ
    Withstand voltage

    Between coil and contact

    AC 4000V 1Min.

    Between contact in the same polarity

    AC 4000V 1Min.

    Impact resistance voltageImpact resistance voltage

    [Measured under the pulsed voltage wave of(1.2x50μs)]

    8000V

    Mechanical properties

    Shock proof

    Malfunvtion Excitation

    490m/s²

    No Excitation

    196m/s²

    Durability

    490m/s²

    Vibration resistant

    Durability

    10~55~10Hz Single amplitude 0.75mm

    (2.94~88.9m/s²)

    Durability

    10~55~10Hz Single amplitude 0.75mm

    (2.94~88.9m/s²)

    Life

    Service life of electric

    Resistive load

    (360 times/hour)

    Over 10000 times(DC 1000V 100A)

    Over 6000 times(DC 1500V 100A)

    Over 50 times(DC 1000V 150A)

    Capacitive load

    Switch on for over 20000 times

    (DC37.5V τ=1ms,

    Shock 150A,Steady state 100A)

    Mechanical service life (3600 times/hour

    Over 1 million times

    Applied environmental temperature

    -40~+85°C

    Applied environmental humidity

    5-85%RH

    Weight (approx.)

    1500g

    ※ Control loop mode: set by the user;

    ※ Rated working system: long-term working system;

  • Description of model naming rules of XGVAC Contactor

    Example:X EV 6 - 100 A / 1500 N - 12   - 1 H 6 L  

                  ①    ③    ④  ⑤    ⑥    ⑦   ⑧  ⑨ ⑩ ⑪⑫ ⑬⑭

    NO.

    Description

    Corporate code

    Contactor for new energy

    Code of shape: "6" for square type, "8" for circular type

    The rated working current for main circuit (DC A)

    The function of auxiliary contact: "A" means that it has the function of auxiliary contact

    The rated working voltage for main circuit (DC V)

    The polarity for main circuit: "N"  is non-polarity

    The control voltage of coil (DCV), "W" is the wide voltage

    The input polarity of coil: "N" is non-polarity

    The number of poles for the contact of main circuit

    The structure of the contact of main circuit: "H" refers to normallyopen, "D" refers to normally close

    The way of the leading-out terminal of main circuit: "3" refers to externally threaded bolt type, "4"  is inserting type, "5" means internally threaded bolt type, "6" refers to the combination of internal thread + connector 

    The way of leading-out terminal of the coil: "L" is outgoing line type, "C" connector type, "B" is the combination of outgoing line+ connector type, "P"refers to the inserting type;

    Derived code

     

    Ordering Instructions

    The following contents shall be stated when ordering:

    1. Name, model and quantity of contactor;

    2. Rated working voltage and rated working current of contactor;

    3. Rated control power supply voltage of contactor;

The DC contactor is widely used in new energy vehicles, charging equipment, photovoltaic/wind power generation, energy storage equipment, cloud servers, high-speed rail, rail transit, ships, aviation, robotics and industrial automation.

● The DC contactor (hereinafter referred to as contactor) is suitable for DC power supply, the main circuit rated voltage DC750V, rated current DC300A below the connection and disconnection of DC power controller;
●The arc extinguishing chamber cavity adopts vacuum brazing ceramic sealing technology, high voltage, high current, double insulation, small size, strong arc extinguishing ability, and the product can ensure no fire or explosion under the correct use;
● The main contact is made of special copper alloy material, with strong breaking capacity, anti-adhesion and long life;
● Arc extinguishing chamber cavity is filled with a certain pressure of inert mixed gas, which can effectively protect the main contact, prevent the main contact from oxidation, and make the main contact break more quickly;
● The product has a built-in control coil energy-saving device, which can reduce the energy consumption of the product;
● The overall protection level of the contactor can reach IP67 level;
● Product implementation of GB/T 14048.4-2020 standards,
● The product meets the IEC60947-4-1:2009 standard,
● Products comply with EU RoHS requirements.

online message