250S/750V HVDC Contactor

The forward and reverse attack rates of the recirculating ball steering gear are very high, so it is easy to operate, has a long life, and works stably and reliably; however, due to the high reverse attack rate, it is easy to transmit the road impact to the steering wheel


Key words:

250S/750V HVDC Contactor

E-mail: xgv@xgvac.com

  • 产品描述
  • Technical Parameters
  • Order specification number
    • Commodity name: 250S/750V HVDC Contactor
    • Commodity ID: XEV8-250S/750-W-1H3L

    DC contactors can be widely used in new energy vehicles and energy storage equipment, charging equipment and photovoltaic, tidal, wind and other green energy power generation systems, rail transit, engineering vehicles, forklifts, leisure and tourism vehicles, cloud servers and UPS, medical equipment, Port electromechanical and construction electromechanical fields are mainly used to switch DC power supplies.

    Key words:
    • HVDC Contactor Wholesale Price
    • Low price HVDC Contactor
    • HVDC Contactor on sales
  • Main technical parameters

    Product model

    XEV8-250S/750-W-1H3L
    XEV8-250S/750-W-1H3L

    Contact

    Contact structure

    1H

    Rated current

    DC 250A

    Rated voltage

    DC 12-750V

    Contact resistance

    <0.5mΩ

    Voltage drop of contact

    (load rated current)

    Below DC 0.1V

    Short-time power current

    400A 10Min.

    Overload cut-off

    DC 450V 375A Over 50 times

    Reverse cut-off

     

    Max. switching current

    DC 320V 1250A(Over 1 time)

    Max.switching voltage

    DC 1000V

    Auxiliary Contact

    The form of auxiliary contact

    1H

    The load rating of auxiliary contact

    DC 30V 2A / AC 125V 3A

    The minimum load of the auxiliary contact

    DC 8V 100mA

    Coil

    Rated control voltage

    DC 12V-36V

    Pull-in time

    Below 75% of the rated control voltage

    Release voltage

    >DC 1V

    Consumed power

    ≈2.5W

    Ope-ration

    Pull-in time

    Below 40ms

    Release time

    Below 20ms

    Service life

    Service life of electric

    (360 times hour)(resistive load)

    10000 times (DC 450V 250A)

    6000 times (DC 750V 250A)

    Mechanical service life

    (3600 times/hour)

    Over 1 million times

    Insulation resistance

    (DC1000V measured

    by tramegger)

    Between Coil and contact

    Over 1000MΩ

    Between contact 

    in the same polarity

    Over 1000MΩ

    Withstand voltage

    Between Coil and contact

    AC4000V 1 min

    Between contact 

    in the same polarity

    AC3000V 1 min

    Applied environmental temperature (No freezing and no condensation)

    -40-+85°C

    Applied environmental humidity

    5-85%RH

    Weight ( approximately )

    450g

     Control loop mode: set by the user;

     Rated work system: long-term work system;

  • Schugway contactor Model naming rule description

    Example: X E V 8 - 250 S / 750 - W - 1 H 3 L 

                            ①        ③                ⑥         ⑦  ⑧     ⑨ ⑩ ⑪ 

    No. 

    Instruction

    Corporate code ;

    Contactor for new energy;

    Code of shape:“8”for square type;

    The rated working current for main circuit (DCA);

    The function of auxiliary contact: “S” means that it

    has the function of auxiliary contact;

    The rated working voltage for main circuit (DCV);

    The control voltage of coil (DCV);  “W” is the wide voltage;

    The number of poles for the contact of main circuit ;

    The structure of the contact of main circuit: “H” refers

    to normally open;

    The way of the leading-out terminal of main circuit:

    “3” refers to externally threaded bolt type,

    The way of leading-out terminal of the coil :

    “L” is outgoing line type.

     

    Order information

    The following should be stated when ordering:

    1, contactor name, model, quantity;

    2, the rated working voltage and rated working current of the contactor;

    3the rated control power voltage of the contactor;

     

    Note: When the model abbreviation is used, - can be omitted.

The DC contactor is widely used in new energy vehicles, charging equipment, photovoltaic/wind power generation, energy storage equipment, cloud servers, high-speed rail, rail transit, ships, aviation, robotics and industrial automation.

● The DC contactor (hereinafter referred to as contactor) is suitable for DC power supply, the main circuit rated voltage DC750V, rated current DC300A below the connection and disconnection of DC power controller;
●The arc extinguishing chamber cavity adopts vacuum brazing ceramic sealing technology, high voltage, high current, double insulation, small size, strong arc extinguishing ability, and the product can ensure no fire or explosion under the correct use;
● The main contact is made of special copper alloy material, with strong breaking capacity, anti-adhesion and long life;
● Arc extinguishing chamber cavity is filled with a certain pressure of inert mixed gas, which can effectively protect the main contact, prevent the main contact from oxidation, and make the main contact break more quickly;
● The product has a built-in control coil energy-saving device, which can reduce the energy consumption of the product;
● The overall protection level of the contactor can reach IP67 level;
● Product implementation of GB/T 14048.4-2020 standards,
● The product meets the IEC60947-4-1:2009 standard,
● Products comply with EU RoHS requirements.

online message