Charging pile DC contactor

The 1000V DC Relay and 1000V DC Contactor is designed based on the magnetic blowing arc extinguishing technology and is suitable for applications such as DC high voltage and large current changes.

The forward and reverse attack rates of the recirculating ball steering gear are very high, so it is easy to operate, has a long life, and works stably and reliably; however, due to the high reverse attack rate, it is easy to transmit the road impact to the steering wheel


Key words:

Charging pile DC contactor

E-mail: xgv@xgvac.com

  • 产品描述
  • Technical Parameters
  • Order specification number
    • Commodity name: Charging pile DC contactor

    The 1000V DC Relay and 1000V DC Contactor is designed based on the magnetic blowing arc extinguishing technology and is suitable for applications such as DC high voltage and large current changes.

    DC contactors can be widely used in new energy vehicles and energy storage equipment, charging equipment and photovoltaic, tidal, wind and other green energy power generation systems, rail transit, engineering vehicles, forklifts, leisure and tourism vehicles, cloud servers and UPS, medical equipment, Port electromechanical and construction electromechanical fields are mainly used to switch DC power supplies.

    The 1000V DC Relay and 1000V DC Contactor Wholesale Price is designed based on the magnetic blowing arc extinguishing technology and is suitable for applications such as DC high voltage and large current changes. Reliable sealing allows the product to be used for a long time in harsh and explosion-proof environments, and its internal components such as coils and contacts are not oxidized. At the same time, the 1000V DC Relay and1000V DC Contactor has the advantages of low energy consumption, less heat generation, long life, small size and light weight. Through the inert gas incoming line arc extinguishing, the purpose of protecting the electrical safety of the equipment is achieved.

     

    Key words:
    • Wholesale Intelligent furniture
    • Intelligent furniture products
    • 1000V DC Contactor Wholesale Price
    • DC Contactor Relay
  • Main technical parameters

    Product model

    XEV6-150/1000-12N-1H6L
    XEV6-150/1000-24N-1H6L

    Contact

    Contact structure

    1H

    Contact resistance

    <0.5mΩ

    Voltage drop of contact(load rated Below  DC 0.1V

    Service life of electric

    current) Resistive load(360 times/hour

    10000 times (DC 750V 150A)

    6000 times (DC 1000V 150A)

    Capacitive load

    Switch on for over 20000 times (DC37.5V,τ=1ms, Shock 180A,Steady state 150A) 

    Rated current

    DC 150A

    Max.switching current

    DC 630V 1200A(Over 1 time)

    Max.switching voltage

    DC 1000V

    Coil

    Rated control voltage

    DC 12V, 24V

    Rated current

    Start DC 12V : 3.5A/300mA

    DC 24V : 1.8A/150mA

    Coil resistance

    Start/Stay at DC 12V: 3.5Ω/40Ω

    DC 24V: 7.8Ω/160Ω

    Pull-in voltage

    Below 75% of the rated controlvoltage

    Release voltage

    Over 10% of the rated control voltage

    Consumed power

    ≈ 40W/4W (Switching time < 0.2s)

    Ope-
    ration5

    Pull-in time

    Below 50ms

    Release time

    Below 30ms

    Impact resistance voltageImpact resistance voltage
    (Measured under the pulsed voltage wave of(12x50μs) 

    4500V

    Mechanical service life (3600 times/hour)

    Over 1 million times

    Insulation resistance
    (DC100V measured
    by tramegger)

    Between Coil and contact

    Over 1000 MΩ

    Between contact
     in the same polarity

    Over 1000 MΩ

    Withstand
     voltage 

    Between Coil and contact

    AC4000V 1 min

    Between contact
     in the same polarity

    AC4000V 1 min

    Applied environmental temperature
    (No freezing and no condensation)

    -40-+85°C 

    Applied environmental humidity

    5-85%RH

    Weight ( approximately )

    650g

     Control loop mode: set by the user;

     Rated work system: long-term work system;

  • Schugway contactor Model naming rule description

    Example: X E V 6150 / 1000  - 12 - 1 H 6 L 

                            ①        ③                               ⑥      ⑦ ⑧ ⑨ ⑩ 

    No. 

    Instruction

    Corporate code ;

    Contactor for new energy;

    Code of shape:“6”for square type;

    The rated working current for main circuit (DCA);

    The rated working voltage for main circuit (DCV);

    The control voltage of coil (DCV);

    The number of poles for the contact of main circuit ;

    The structure of the contact of main circuit:“H”refers
    to normally open;

    The way of the leading-out terminal of main circuit:
    “6” refers to the combination of internal thread + connector ;

    The way of leading-out terminal of the coil: 
    “L” is outgoing line type.

     

    Order information

    The following should be stated when ordering:

    1, contactor name, model, quantity;

    2, the rated working voltage and rated working current of the contactor;

    3the rated control power voltage of the contactor;

     

    Note: When the model abbreviation is used, ⑥ - ⑩ can be omitted.

The DC contactor is widely used in new energy vehicles, charging equipment, photovoltaic/wind power generation, energy storage equipment, cloud servers, high-speed rail, rail transit, ships, aviation, robotics and industrial automation.

● The DC contactor (hereinafter referred to as contactor) is suitable for DC power supply, the main circuit rated voltage DC750V, rated current DC300A below the connection and disconnection of DC power controller;
●The arc extinguishing chamber cavity adopts vacuum brazing ceramic sealing technology, high voltage, high current, double insulation, small size, strong arc extinguishing ability, and the product can ensure no fire or explosion under the correct use;
● The main contact is made of special copper alloy material, with strong breaking capacity, anti-adhesion and long life;
● Arc extinguishing chamber cavity is filled with a certain pressure of inert mixed gas, which can effectively protect the main contact, prevent the main contact from oxidation, and make the main contact break more quickly;
● The product has a built-in control coil energy-saving device, which can reduce the energy consumption of the product;
● The overall protection level of the contactor can reach IP67 level;
● Product implementation of GB/T 14048.4-2020 standards,
● The product meets the IEC60947-4-1:2009 standard,
● Products comply with EU RoHS requirements.