    DC contactors can be widely used in new energy vehicles and energy storage equipment, charging equipment and photovoltaic, tidal, wind and other green energy power generation systems, rail transit, engineering vehicles, forklifts, leisure and tourism vehicles, cloud servers and UPS, medical equipment, Port electromechanical and construction electromechanical fields are mainly used to switch DC power supplies.

  • Main technical parameters

    Product model

    XEV6-60/750-12N-1H5L
    XEV6-60/750-24N-1H5L

    Contact

    Contact structure

    1H

    Contact resistance

    <0.5mΩ

    Voltage drop of contact(load rated Below  DC 0.2V

    Service life of electric

    current) Resistive load(360 times/hour

    Over10000 times (DC 450V 60A)

    Over6000 times (DC 750V 60A)

    Capacitive load

     

    Rated current

    DC 60A

    Max.switching current

    DC 300V 500A(Over 1 time)

    Max.switching voltage

    DC 1000V

    Coil

    Rated control voltage

    DC 12V, 24V

    Rated current

    DC 12V: 417mA

    DC 24V: 208mA

    Coil resistance

    DC 12V: 28.8Ω

    DC 24V: 115.2Ω

    Pull-in voltage

    Below 75% of the rated controlvoltage

    Release voltage

    Over 10% of the rated control voltage

    Consumed power

    ≈5W

    Ope-
    ration5

    Pull-in time

    Below 50ms

    Release time

    Below 30ms

    Impact resistance voltageImpact resistance voltage
    (Measured under the pulsed voltage wave of(12x50μs) 

    4000V

    Mechanical service life (3600 times/hour)

    Over 1 million times

    Insulation resistance
    (DC100V measured
    by tramegger)

    Between Coil and contact

    Over 1000 MΩ

    Between contact
     in the same polarity

    Over 1000 MΩ

    Withstand
     voltage 

    Between Coil and contact

    AC2500V 1 min

    Between contact
     in the same polarity

    AC2500V 1 min

    Applied environmental temperature
    (No freezing and no condensation)

    -40-+85°C 

    Applied environmental humidity

    5-85%RH

    Weight ( approximately )

    320g

     Control loop mode: set by the user;

     Rated work system: long-term work system;

  • Schugway contactor Model naming rule description

    Example: X E V 660  / 750 - 12 N - 1 H 5 L

                            ①        ③                           ⑥   ⑦     ⑧ ⑨ ⑩ ⑪ 

    No. 

    Instruction

    Corporate code ;

    Contactor for new energy;

    Code of shape:“6”for square type;

    The rated working current for main circuit (DCA);

    The rated working voltage for main circuit (DCV);

    The control voltage of coil (DCV);

    The input polarity of coil:“N”is non-polarity;

    The number of poles for the contact of main circuit ;

    The structure of the contact of main circuit:“H”refers
    to normally open;

    The way of the leading-out terminal of main circuit:
    “5” means internally threaded bolt type;

    The way of leading-out terminal of the coil:
    “L” is outgoing line type.

     

    Order information

    The following should be stated when ordering:

    1, contactor name, model, quantity;

    2, the rated working voltage and rated working current of the contactor;

    3the rated control power voltage of the contactor;

     

    Note: When the model abbreviation is used, ⑥ - ⑪ can be omitted.

The DC contactor is widely used in new energy vehicles, charging equipment, photovoltaic/wind power generation, energy storage equipment, cloud servers, high-speed rail, rail transit, ships, aviation, robotics and industrial automation.

● The DC contactor (hereinafter referred to as contactor) is suitable for DC power supply, the main circuit rated voltage DC750V, rated current DC300A below the connection and disconnection of DC power controller;
●The arc extinguishing chamber cavity adopts vacuum brazing ceramic sealing technology, high voltage, high current, double insulation, small size, strong arc extinguishing ability, and the product can ensure no fire or explosion under the correct use;
● The main contact is made of special copper alloy material, with strong breaking capacity, anti-adhesion and long life;
● Arc extinguishing chamber cavity is filled with a certain pressure of inert mixed gas, which can effectively protect the main contact, prevent the main contact from oxidation, and make the main contact break more quickly;
● The product has a built-in control coil energy-saving device, which can reduce the energy consumption of the product;
● The overall protection level of the contactor can reach IP67 level;
● Product implementation of GB/T 14048.4-2020 standards,
● The product meets the IEC60947-4-1:2009 standard,
● Products comply with EU RoHS requirements.

online message